AES Environmental Recirculating Fume Cabinet ...
These cabinets are designed and manufactured to fully comply with Australian Standard AS2243.9: Recirculating Fume Cabinets.
These Recirculating Fume Cabinets are suitable for benchtop use and supplied with a stainless-steel work tray. When supplied without the work tray, the cabinet may be installed over a sink or an item of equipment. RFC cabinets can also be supplied with a special trolley or stand, allowing a separate trolley to be wheeled into the containment enclosure. The mobility of trolley-mounted RFC cabinets is a significant advantage in hospitals or large research institutions, where materials such as glutaraldehyde are handled at multiple locations. These applications include endoscope sterilisation.
The RFC cabinet has an inward air velocity maintained at > 0.5 m/s +/-20% for both benchtop and trolley-mounted installations. In most applications, filtered exhaust air may be discharged to the room. This avoids the air supply system problems that arise with ducted cabinets. In special cases, where the nature or concentration of the contaminant indicates, the cabinet exhaust may be connected to an exhaust fan/ duct system that discharges to atmosphere.
RFC cabinets are produced in two sizes, with 900 or 1200 mm nominal work zone width.
Filtration air exhausted from the top of the cabinet is filtered by a two-stage filtration system. A prefilter protects the final filter system from particulates > 5µm. The final activated carbon filter incorporates carbon granules with a selected chemical impregnation to optimise the arrestance of specific vapours. Specific impregnations are available for the handling of a wide range of contaminants, including formaldehyde and glutaraldehyde, Alkaline odours, Ammonia and amines, Inorganic acids and acidic odours, H2S and mercaptans and HCN.
Special adsorption filters are fitted for the capture of a wide range of vapours. Chemical impregnation of the carbon produces a chemical reaction similar to an oxidation process when the contaminant is adsorbed. This process extends filter life as the surface of the catalyst will not be covered by molecules trapped on it, thus enabling the process to be repeated. These filters will operate effectively in environments with temperatures up to 70oC and relative humidity up to 80%.
The cabinets outer casing is constructed from galvanized steel and powder-coated to AS2700 while the work zone is constructed in 304 stainless steel. A removable aluminium screen is fitted in front of the prefilter at the rear of the work zone. A variable speed controller regulates a direct drive motor/blower to enable the airflow to be maintained through filter life.
An easily-accessed, disposable polyester pre filter arrests not less than 90% of particulates > 5µm, thus prolonging carbon filter life. A warning light in the control panel signals the need for pre filter service.
Products supplied by Thermoline are factory-tested to ensure compliance and performance targets are met.
Additional testing and certification is recommended as follows:
To contact Thermoline Scientific Equipment about AES Environmental Recirculating Fume Cabinet use Get a quote.
These cabinets are designed and manufactured to fully comply with Australian Standard AS2243.9: Recirculating Fume Cabinets.
These Recirculating Fume Cabinets are suitable for benchtop use and supplied with a stainless-steel work tray. When supplied without the work tray, the cabinet may be installed over a sink or an item of equipment. RFC cabinets can also be supplied with a special trolley or stand, allowing a separate trolley to be wheeled into the containment enclosure. The mobility of trolley-mounted RFC cabinets is a significant advantage in hospitals or large research institutions, where materials such as glutaraldehyde are handled at multiple locations. These applications include endoscope sterilisation.
The RFC cabinet has an inward air velocity maintained at > 0.5 m/s +/-20% for both benchtop and trolley-mounted installations. In most applications, filtered exhaust air may be discharged to the room. This avoids the air supply system problems that arise with ducted cabinets. In special cases, where the nature or concentration of the contaminant indicates, the cabinet exhaust may be connected to an exhaust fan/ duct system that discharges to atmosphere.
RFC cabinets are produced in two sizes, with 900 or 1200 mm nominal work zone width.
Filtration air exhausted from the top of the cabinet is filtered by a two-stage filtration system. A prefilter protects the final filter system from particulates > 5µm. The final activated carbon filter incorporates carbon granules with a selected chemical impregnation to optimise the arrestance of specific vapours. Specific impregnations are available for the handling of a wide range of contaminants, including formaldehyde and glutaraldehyde, Alkaline odours, Ammonia and amines, Inorganic acids and acidic odours, H2S and mercaptans and HCN.
Special adsorption filters are fitted for the capture of a wide range of vapours. Chemical impregnation of the carbon produces a chemical reaction similar to an oxidation process when the contaminant is adsorbed. This process extends filter life as the surface of the catalyst will not be covered by molecules trapped on it, thus enabling the process to be repeated. These filters will operate effectively in environments with temperatures up to 70oC and relative humidity up to 80%.
The cabinets outer casing is constructed from galvanized steel and powder-coated to AS2700 while the work zone is constructed in 304 stainless steel. A removable aluminium screen is fitted in front of the prefilter at the rear of the work zone. A variable speed controller regulates a direct drive motor/blower to enable the airflow to be maintained through filter life.
An easily-accessed, disposable polyester pre filter arrests not less than 90% of particulates > 5µm, thus prolonging carbon filter life. A warning light in the control panel signals the need for pre filter service.
Products supplied by Thermoline are factory-tested to ensure compliance and performance targets are met.
Additional testing and certification is recommended as follows:
To contact Thermoline Scientific Equipment about AES Environmental Recirculating Fume Cabinet use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product