AES Environmental Vertical Laminar Flow ...
In the VWS series, air is passed through the work zone in a smooth, vertical direction, and the blower fan and mounting position are designed to maximise airflow. The deeper rear plenum ensures unobstructed airflow to the HEPA filter face. As a result, the cabinet is quieter, with reduced vibration and longer service life for the HEPA filter.
The cabinet housing is constructed of locally sourced steel and consists of a high-quality powder-coated finish to provide a suitably solvent, alkali and acid-resistant laboratory-grade coating. The work area is fully constructed from stainless steel, with inward folds to avoid sharp edges. A removable, washable metal screen protects the HEPA filter from mechanical damage.
A direct-drive fan is regulated by a speed controller to enable airflow to be maintained through filter life. Fans and filter plenums are designed to provide quiet operation and low vibration levels.
Clyde-Apac Microseal HEPA filters are manufactured to AS 4260. Each filter is individually tested to be leak-free in accordance with AS 1807.6. A manufacturer-endorsed test label fitted with an extract of the test report is affixed to each filter. A prefilter extends the life of the exhaust HEPA filter and protects it from mechanical damage during the cleaning of the work zone.
An easily-accessed, washable pre filter arrests not less than 90% of particles 5 microns and larger, thus prolonging HEPA filter life. A warning light in the control panel signals the need for pre filter service.
A low-voltage touch control panel is located on the front of the cabinet. Glare-free lamps provide a minimum lighting intensity of min 650 lux at the work floor.
VWS cabinets provide protection for products or experiments, but do not protect personnel from aerosols of hazardous materials that may be handled in the cabinet. For applications where personnel and environmental protection is required, Clyde- Apac Class I or Class II biological safety cabinets, or cytotoxic drug safety cabinets (as applicable) should be considered.
Typical applications include: Aseptic dispensing, Assembly of electronics and optics components, Cell culturing, Media pouring, Preparation of medical devices and Sterility testing. VWS Series Laminar Flow cabinets are intended for work with non-hazardous materials in such applications.
To contact Thermoline Scientific Equipment about AES Environmental Vertical Laminar Flow Cabinets use Get a quote.
In the VWS series, air is passed through the work zone in a smooth, vertical direction, and the blower fan and mounting position are designed to maximise airflow. The deeper rear plenum ensures unobstructed airflow to the HEPA filter face. As a result, the cabinet is quieter, with reduced vibration and longer service life for the HEPA filter.
The cabinet housing is constructed of locally sourced steel and consists of a high-quality powder-coated finish to provide a suitably solvent, alkali and acid-resistant laboratory-grade coating. The work area is fully constructed from stainless steel, with inward folds to avoid sharp edges. A removable, washable metal screen protects the HEPA filter from mechanical damage.
A direct-drive fan is regulated by a speed controller to enable airflow to be maintained through filter life. Fans and filter plenums are designed to provide quiet operation and low vibration levels.
Clyde-Apac Microseal HEPA filters are manufactured to AS 4260. Each filter is individually tested to be leak-free in accordance with AS 1807.6. A manufacturer-endorsed test label fitted with an extract of the test report is affixed to each filter. A prefilter extends the life of the exhaust HEPA filter and protects it from mechanical damage during the cleaning of the work zone.
An easily-accessed, washable pre filter arrests not less than 90% of particles 5 microns and larger, thus prolonging HEPA filter life. A warning light in the control panel signals the need for pre filter service.
A low-voltage touch control panel is located on the front of the cabinet. Glare-free lamps provide a minimum lighting intensity of min 650 lux at the work floor.
VWS cabinets provide protection for products or experiments, but do not protect personnel from aerosols of hazardous materials that may be handled in the cabinet. For applications where personnel and environmental protection is required, Clyde- Apac Class I or Class II biological safety cabinets, or cytotoxic drug safety cabinets (as applicable) should be considered.
Typical applications include: Aseptic dispensing, Assembly of electronics and optics components, Cell culturing, Media pouring, Preparation of medical devices and Sterility testing. VWS Series Laminar Flow cabinets are intended for work with non-hazardous materials in such applications.
To contact Thermoline Scientific Equipment about AES Environmental Vertical Laminar Flow Cabinets use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product