BioSan CH-100 dry block heater and cooler ...
Key Features
The BioSan CH-100 dry block heater and cooler is an ideal alternative to ice buckets for keeping samples and reagents cool while on the lab bench. The instrument can be configured with one of three different aluminium block options (please see below).
The heating/cooling range for the CH-100 is from -10°C to +100°C and the current and set temperatures are shown on an LCD display. The lid of the dry block bath can be closed to provide operator protection from hot blocks and to increase temperature stability. The unit is controlled through a touch pad.
Heating and cooling times to reach specific temperatures are as follows:
From +25°C to +37°C | 3 minutes |
From +25°C to +100°C | 16 minutes |
From +25°C to -10°C | 21 minutes |
From +100°C to -10°C | 28 minutes |
Block options
The following aluminium block options are available for the CH-100:
CH-1 | Block for 20 x 0.5 mL and 12 x 1.5 mL microtubes |
CH-2 | Block for 20 x 1.5 mL microtubes |
CH-3 | Block for 20 x 2 mL microtubes |
Specifications
Manufacturer | BioSan |
Model number | CH-100 |
Temperature setting range | -10°C to +100°C |
Temperature setting resolution | 0.1°C |
Temperature control range | 30°C below ambient to +100°C |
Temperature stability | ±0.1°C |
Temperature uniformity at 37°C | ±0.1°C |
Timer range | 1 minute to 96 hours in increments of 1 minute or continuous |
Block options | Three (please see above) |
Instrument dimensions (W x D x H) | 240 mm x 260 mm x 165 mm |
Display | LCD |
Weight | 3.2 Kg |
Power requirements | Input: 100 - 240 VAC 50/60 Hz | Output: 12 VDC |
To contact Advance Scientific Products Pty Ltd about BioSan CH-100 dry block heater and cooler with multiple sample block options use Get a quote.
Key Features
The BioSan CH-100 dry block heater and cooler is an ideal alternative to ice buckets for keeping samples and reagents cool while on the lab bench. The instrument can be configured with one of three different aluminium block options (please see below).
The heating/cooling range for the CH-100 is from -10°C to +100°C and the current and set temperatures are shown on an LCD display. The lid of the dry block bath can be closed to provide operator protection from hot blocks and to increase temperature stability. The unit is controlled through a touch pad.
Heating and cooling times to reach specific temperatures are as follows:
From +25°C to +37°C | 3 minutes |
From +25°C to +100°C | 16 minutes |
From +25°C to -10°C | 21 minutes |
From +100°C to -10°C | 28 minutes |
Block options
The following aluminium block options are available for the CH-100:
CH-1 | Block for 20 x 0.5 mL and 12 x 1.5 mL microtubes |
CH-2 | Block for 20 x 1.5 mL microtubes |
CH-3 | Block for 20 x 2 mL microtubes |
Specifications
Manufacturer | BioSan |
Model number | CH-100 |
Temperature setting range | -10°C to +100°C |
Temperature setting resolution | 0.1°C |
Temperature control range | 30°C below ambient to +100°C |
Temperature stability | ±0.1°C |
Temperature uniformity at 37°C | ±0.1°C |
Timer range | 1 minute to 96 hours in increments of 1 minute or continuous |
Block options | Three (please see above) |
Instrument dimensions (W x D x H) | 240 mm x 260 mm x 165 mm |
Display | LCD |
Weight | 3.2 Kg |
Power requirements | Input: 100 - 240 VAC 50/60 Hz | Output: 12 VDC |