Thyroid Biopsy Ultrasound Training Model
Using Blue Phantom simulated human tissue, this very realistic and ultra-durable thyroid biopsy ultrasound training model is excellent for training clinicians in the psychomotor skills associated with ultrasound guided fine needle biopsies of the thyroid gland.
These ultrasound imaging skills include; using ultrasound system controls, transducer positioning and movement, recognition of thyroid and surrounding structural anatomy, identification of a variety of masses present in the thyroid gland, using ultrasound system calculation packages, and using ultrasound to target the lesions for fine needle biopsies.
Learn to use ultrasound to identify thyroid pathology and target lesions for fine needle biopsies.
Our highly realistic ultrasound training model contains the thyroid, focal lesions suitable for fine needle biopsy, and pertinent surrounding anatomical structures. The anatomical structured contained within the thyroid ultrasound training model include: the left and right lobes of the thyroid gland as well as the isthmus, a multinodular goiter, multiple masses of varying sonographic appearances, trachea, esophagus, carotid arteries, and internal jugular veins. Multiple simple and complex masses with a variety of sonographic appearances are present in the model including; hypoechoic, echogenic, echolucent with an echogenic rim, and echogenic with a echolucent rim.
This medical ultrasound training phantom is constructed using Blue Phantom’s patented ultra-durable tissue and is extremely realistic in ultrasound imaging characteristics and feels like real human tissue. The masses in this soft tissue biopsy model can be accessed with needles as well as fluid can be injected into the model to verify needle tip location. Fluids are automatically expelled so that the model can be used repeatedly for training.
We recommend that you utilize 18 – 21 gauge sharp, unbent needles during your training in order to maximize the self healing and ultra-durable performance of the breast ultrasound training model. While you are able to perform core biopsies and actually remove tissue from the tumors in the model, do this knowing that each mass can only withstand core biopsy until the lesion is destroyed which will require that you then move on to another mass located in the training model.
This thyroid ultrasound trainer will perform well using any ultrasound imaging system configured with the appropriate transducer (recommended ultrasound transducer; high frequency linear array ultrasound probe 7.5 – 15 MHz). Our uncompromising quality allows clinicians to utilize the model and repeatedly practice the procedure without the high costs of replacing disposable parts. This ultrasound phantom model is excellent for specialties including thyroid surgery, surgical training programs, endocrinology training programs, radiology training programs, ultrasound training programs, simulation centers, surgical skills centers, medical education facilities, and ultrasound manufacturers for ultrasound education and demonstrations.
To contact Ultrasound Accessories Group about Thyroid Biopsy Ultrasound Training Model use Get a quote.
Using Blue Phantom simulated human tissue, this very realistic and ultra-durable thyroid biopsy ultrasound training model is excellent for training clinicians in the psychomotor skills associated with ultrasound guided fine needle biopsies of the thyroid gland.
These ultrasound imaging skills include; using ultrasound system controls, transducer positioning and movement, recognition of thyroid and surrounding structural anatomy, identification of a variety of masses present in the thyroid gland, using ultrasound system calculation packages, and using ultrasound to target the lesions for fine needle biopsies.
Learn to use ultrasound to identify thyroid pathology and target lesions for fine needle biopsies.
Our highly realistic ultrasound training model contains the thyroid, focal lesions suitable for fine needle biopsy, and pertinent surrounding anatomical structures. The anatomical structured contained within the thyroid ultrasound training model include: the left and right lobes of the thyroid gland as well as the isthmus, a multinodular goiter, multiple masses of varying sonographic appearances, trachea, esophagus, carotid arteries, and internal jugular veins. Multiple simple and complex masses with a variety of sonographic appearances are present in the model including; hypoechoic, echogenic, echolucent with an echogenic rim, and echogenic with a echolucent rim.
This medical ultrasound training phantom is constructed using Blue Phantom’s patented ultra-durable tissue and is extremely realistic in ultrasound imaging characteristics and feels like real human tissue. The masses in this soft tissue biopsy model can be accessed with needles as well as fluid can be injected into the model to verify needle tip location. Fluids are automatically expelled so that the model can be used repeatedly for training.
We recommend that you utilize 18 – 21 gauge sharp, unbent needles during your training in order to maximize the self healing and ultra-durable performance of the breast ultrasound training model. While you are able to perform core biopsies and actually remove tissue from the tumors in the model, do this knowing that each mass can only withstand core biopsy until the lesion is destroyed which will require that you then move on to another mass located in the training model.
This thyroid ultrasound trainer will perform well using any ultrasound imaging system configured with the appropriate transducer (recommended ultrasound transducer; high frequency linear array ultrasound probe 7.5 – 15 MHz). Our uncompromising quality allows clinicians to utilize the model and repeatedly practice the procedure without the high costs of replacing disposable parts. This ultrasound phantom model is excellent for specialties including thyroid surgery, surgical training programs, endocrinology training programs, radiology training programs, ultrasound training programs, simulation centers, surgical skills centers, medical education facilities, and ultrasound manufacturers for ultrasound education and demonstrations.
To contact Ultrasound Accessories Group about Thyroid Biopsy Ultrasound Training Model use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product