3-step easy measurement
Using the item code recorded on the slide, the item and lot number are automatically identified. After pressing the start key everything through the printing of the measurement data is fully automatic.
One pack panels (S-panels)
Set multiple required items at once
One pack panels are also available. There is no need to open individually packed slides in a panel. This improves work efficiency and reduces waste.
Individually packed slides in a panel
Simply place it in the slide cartridge and remove the binding tape
Measure directly from whole blood
Built-in centrifugal separation unit*1
Simply insert the whole blood in the dedicated IC cup and place the cup in the unit. Automatically execute everything from plasma extraction to analysis.
*1 NX600V IC
Can also measure serum and plasma separated by external centrifugation
This is possible when there is a need to reduce the amount of blood sampled or use the plasma sample in other tests.
Continuous measurement
Reduce waiting time
As soon as the pipetting procedure for the first sample is completed, the slides for the next sample can already be set and the test started. This minimizes waiting time for your patients.
Set consumables for multiple samples at once
The layout is simpler than our previous models, and this makes it easier to set consumables.
Multiple tips can be set at once, which eliminates the need to set reference solution for each measurement. This reduces the frequency of consumable replacement.
Large 7-inch intuitive LCD touch panel
The simple and easy-to-use operation screen provides a swift transition speed of 0.5 seconds or less for stress-free operation. A rich variety of help screens are also provided. This enables easy operation while checking illustrated usage and maintenance procedures.
A rich variety of functions for flexible support
Microsample testing
Only 10 μL of sample is required for each test. (CRP: 5μL/test, ISE: 50μL/test, dead volume is necessary using automatic measurement.) A very useful feature especially in small animals. If there is less sample, measurement can be done by manual pipetting.
High throughput
128 tests can be processed per hour.
Automatic dilution function
Labor intensive operations like dispensing, mixing etc. are automated. The only user operation required is when selecting the dilution ratio.
No Calibration
The FUJI DRI-CHEM system uses dry type reagents which are very stable. As the reagents are stable, calibration is not necessary and it utilizes a standard curve for the measurements. Variability in the reagent lots are adjusted using the QC card.
* ISE:Calibration and correction are not necessary. QC card is not attached.
Easy reagent lot information input by QC card
Information for every reagent lot that are needed for the measurement are easily input into the machine using the QC card.
Reduces biohazard risks
Used slides and tips fall automatically into a disposal box. Reduces the risk of contact with specimens.
Achieve high-precision testing with reliable technology
High-quality slides utilize coating technology cultivated in the field of photography.
To contact Fujifilm about Vet Point-Of-Care Chemistry Analyser | DRI-CHEM NX600V use Get a quote.
3-step easy measurement
Using the item code recorded on the slide, the item and lot number are automatically identified. After pressing the start key everything through the printing of the measurement data is fully automatic.
One pack panels (S-panels)
Set multiple required items at once
One pack panels are also available. There is no need to open individually packed slides in a panel. This improves work efficiency and reduces waste.
Individually packed slides in a panel
Simply place it in the slide cartridge and remove the binding tape
Measure directly from whole blood
Built-in centrifugal separation unit*1
Simply insert the whole blood in the dedicated IC cup and place the cup in the unit. Automatically execute everything from plasma extraction to analysis.
*1 NX600V IC
Can also measure serum and plasma separated by external centrifugation
This is possible when there is a need to reduce the amount of blood sampled or use the plasma sample in other tests.
Continuous measurement
Reduce waiting time
As soon as the pipetting procedure for the first sample is completed, the slides for the next sample can already be set and the test started. This minimizes waiting time for your patients.
Set consumables for multiple samples at once
The layout is simpler than our previous models, and this makes it easier to set consumables.
Multiple tips can be set at once, which eliminates the need to set reference solution for each measurement. This reduces the frequency of consumable replacement.
Large 7-inch intuitive LCD touch panel
The simple and easy-to-use operation screen provides a swift transition speed of 0.5 seconds or less for stress-free operation. A rich variety of help screens are also provided. This enables easy operation while checking illustrated usage and maintenance procedures.
A rich variety of functions for flexible support
Microsample testing
Only 10 μL of sample is required for each test. (CRP: 5μL/test, ISE: 50μL/test, dead volume is necessary using automatic measurement.) A very useful feature especially in small animals. If there is less sample, measurement can be done by manual pipetting.
High throughput
128 tests can be processed per hour.
Automatic dilution function
Labor intensive operations like dispensing, mixing etc. are automated. The only user operation required is when selecting the dilution ratio.
No Calibration
The FUJI DRI-CHEM system uses dry type reagents which are very stable. As the reagents are stable, calibration is not necessary and it utilizes a standard curve for the measurements. Variability in the reagent lots are adjusted using the QC card.
* ISE:Calibration and correction are not necessary. QC card is not attached.
Easy reagent lot information input by QC card
Information for every reagent lot that are needed for the measurement are easily input into the machine using the QC card.
Reduces biohazard risks
Used slides and tips fall automatically into a disposal box. Reduces the risk of contact with specimens.
Achieve high-precision testing with reliable technology
High-quality slides utilize coating technology cultivated in the field of photography.
To contact Fujifilm about Vet Point-Of-Care Chemistry Analyser | DRI-CHEM NX600V use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product