Robust equipment easy to handle , mounted in tubular frame plate in high resistance plastic resin finishing. .
Description
Documents
In Stock
Product Description
External finishing in white resistant to the lab environment and products as xylol .
Micro-processed central digital touch screen LCD panel , which controls all functions of equipment such as : date , time and year and equipment adjustment parameters configuration.
Daily schedule for 24 hours and sloe time for weekends or extended holidays
Changeable programming with selectable time interval according to the need of the operator . Ability to pause processing in any bath or position
Adjustable bath speed and time control allowing total flow fully preventing contamination of one bath to other
High duration battery own up to 10 years allowing data protection even in lack of power situations
+/- 20 min continuous operation in lack of power situation . Energy provided by no break variable according to no break capacity
Protection sensor that controls paraffin mugs individually with visual and sonorous alarm protection for sub and super heating
System protection not allowing the penetration of the last xylol paraffin bath , in case of not agreeable selected temperature parameter
Automatic stop at end of cycle system , 9 storage protocols programs pre-selected by operator .
System oscillation inox basket with capacity up to 85 cassettes with improves the processed material quality
Product Specification
Paraffin Bath
Temperature Control in panel , with adjustable sensitivity to 80±1C
Capacity up to 255 plastic cassettes using 3 baskets
Capacity to 10 Reagent baths and 2 paraffin baths , total 12 baths of 2L each
Sealant bath lid that fully prevent environment contamination
To contact Amos Scientific about Amos Scientific Carousel Tissue Processor | ATP200 use Get a quote.
Product Description
External finishing in white resistant to the lab environment and products as xylol .
Micro-processed central digital touch screen LCD panel , which controls all functions of equipment such as : date , time and year and equipment adjustment parameters configuration.
Daily schedule for 24 hours and sloe time for weekends or extended holidays
Changeable programming with selectable time interval according to the need of the operator . Ability to pause processing in any bath or position
Adjustable bath speed and time control allowing total flow fully preventing contamination of one bath to other
High duration battery own up to 10 years allowing data protection even in lack of power situations
+/- 20 min continuous operation in lack of power situation . Energy provided by no break variable according to no break capacity
Protection sensor that controls paraffin mugs individually with visual and sonorous alarm protection for sub and super heating
System protection not allowing the penetration of the last xylol paraffin bath , in case of not agreeable selected temperature parameter
Automatic stop at end of cycle system , 9 storage protocols programs pre-selected by operator .
System oscillation inox basket with capacity up to 85 cassettes with improves the processed material quality
Product Specification
Paraffin Bath
Temperature Control in panel , with adjustable sensitivity to 80±1C
Capacity up to 255 plastic cassettes using 3 baskets
Capacity to 10 Reagent baths and 2 paraffin baths , total 12 baths of 2L each
Sealant bath lid that fully prevent environment contamination