Atherton Biological Indicators | Rapid ...
The perfect companion to the rapid readout biological system. Biological indicators are used for biological monitoring of Hydrogen Peroxide Low Temperature Plasma Sterilizer. The whole process goes as follows: sterilize the biological indicator together with sterilization articles (please do not break biological indicator when sterilizing) and take out the indicator after sterilization and break it; and then put it into incubator for monitoring spores growth. If with growth, the culture medium colour would turn yellow and if not, no colour changes on culture medium. The final incubation result will out in corresponding hours.
Model |
FUSBI0102-2 |
FUSBI0502 |
Packing |
50pcx/Box |
50pcx/Box |
Organism |
G-stearothermophiIus ATCC7953 |
G-stearothermophiIus ATCC7953 |
Population (Mean/strip) |
≥1.0x106c.f.u. |
≥1.0x106c.f.u. |
D-Value |
≥1s (50°C,5mg/L VH2O2) |
0.75-8s(50°C,2.3mg/L VH2O2) |
Incubation Time |
4-20mins (readout) |
24-48H |
Standard |
Test 1 time every for sterilization cycle |
Test 1 time every for sterilization cycle |
Features of this product
Reorder Number
To contact Atherton about Atherton Biological Indicators | Rapid reading biological indicators (H2O2) use Get a quote.
The perfect companion to the rapid readout biological system. Biological indicators are used for biological monitoring of Hydrogen Peroxide Low Temperature Plasma Sterilizer. The whole process goes as follows: sterilize the biological indicator together with sterilization articles (please do not break biological indicator when sterilizing) and take out the indicator after sterilization and break it; and then put it into incubator for monitoring spores growth. If with growth, the culture medium colour would turn yellow and if not, no colour changes on culture medium. The final incubation result will out in corresponding hours.
Model |
FUSBI0102-2 |
FUSBI0502 |
Packing |
50pcx/Box |
50pcx/Box |
Organism |
G-stearothermophiIus ATCC7953 |
G-stearothermophiIus ATCC7953 |
Population (Mean/strip) |
≥1.0x106c.f.u. |
≥1.0x106c.f.u. |
D-Value |
≥1s (50°C,5mg/L VH2O2) |
0.75-8s(50°C,2.3mg/L VH2O2) |
Incubation Time |
4-20mins (readout) |
24-48H |
Standard |
Test 1 time every for sterilization cycle |
Test 1 time every for sterilization cycle |
Features of this product
Reorder Number
To contact Atherton about Atherton Biological Indicators | Rapid reading biological indicators (H2O2) use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product