Biological indicators are used for biological monitoring of Hydrogen Peroxide Low Temperature Plasma Sterilizer.
Description
The perfect companion to the rapid readout biological system. Biological indicators are used for biological monitoring of Hydrogen Peroxide Low Temperature Plasma Sterilizer. The whole process goes as follows: sterilize the biological indicator together with sterilization articles (please do not break biological indicator when sterilizing) and take out the indicator after sterilization and break it; and then put it into incubator for monitoring spores growth. If with growth, the culture medium colour would turn yellow and if not, no colour changes on culture medium. The final incubation result will out in corresponding hours.
Model
FUSBI0102-2
FUSBI0502
Packing
50pcx/Box
50pcx/Box
Organism
G-stearothermophiIus ATCC7953
G-stearothermophiIus ATCC7953
Population (Mean/strip)
≥1.0x106c.f.u.
≥1.0x106c.f.u.
D-Value
≥1s (50°C,5mg/L VH2O2)
0.75-8s(50°C,2.3mg/L VH2O2)
Incubation Time
4-20mins (readout)
24-48H
Standard
Test 1 time every for sterilization cycle
Test 1 time every for sterilization cycle
Features of this product
Get results in under 20 minutes ensuring the quarantine of every load, eliminating recalls and reducing the costs of fighting cross- infection
Significantly reduce the risk of cross infection with self-contained biological indicators that minimise false positives and give more accurate results
Compatible with both steam and H2O2 sterilization cycles
To contact Atherton about Atherton Biological Indicators | Rapid reading biological indicators (H2O2) use Get a quote.
The perfect companion to the rapid readout biological system. Biological indicators are used for biological monitoring of Hydrogen Peroxide Low Temperature Plasma Sterilizer. The whole process goes as follows: sterilize the biological indicator together with sterilization articles (please do not break biological indicator when sterilizing) and take out the indicator after sterilization and break it; and then put it into incubator for monitoring spores growth. If with growth, the culture medium colour would turn yellow and if not, no colour changes on culture medium. The final incubation result will out in corresponding hours.
Model
FUSBI0102-2
FUSBI0502
Packing
50pcx/Box
50pcx/Box
Organism
G-stearothermophiIus ATCC7953
G-stearothermophiIus ATCC7953
Population (Mean/strip)
≥1.0x106c.f.u.
≥1.0x106c.f.u.
D-Value
≥1s (50°C,5mg/L VH2O2)
0.75-8s(50°C,2.3mg/L VH2O2)
Incubation Time
4-20mins (readout)
24-48H
Standard
Test 1 time every for sterilization cycle
Test 1 time every for sterilization cycle
Features of this product
Get results in under 20 minutes ensuring the quarantine of every load, eliminating recalls and reducing the costs of fighting cross- infection
Significantly reduce the risk of cross infection with self-contained biological indicators that minimise false positives and give more accurate results
Compatible with both steam and H2O2 sterilization cycles
Customers: Calvary Health Care, Ramsay Health Care, Most major public hospitals,
Trade With Confidence. The supplier of this item is approved as a Verified Supplier. Business registration, contact details and locations have been verified. Atherton are also proudly displaying these credentials:
Established:
1889
Employees:
51-200
Customers:
Calvary Health Care, Ramsay Health Care, Most major public hospitals,