CSO Sirius+ | Topographer & Tomographer
Sirius+ combines placido disk topography with Scheimpflug tomography of the anterior segment providing information on pachymetry, elevation, curvature and dioptric power of both corneal surfaces over a diameter of 12 mm. All biometric measurements of the anterior chamber are calculated using up to 100 HR corneal sections. Measurement speed reduces the effect of eye movement producing a high quality accurate measurement.
In addition to the clinical diagnosis of the anterior segment the most common uses are: refractive and cataract surgery, an IOL calculation module is available.
Objective examinations provide an accurate measurement of pupil diameter in scotopic, mesopic and photopic conditions.
KERATOCONOUS SCREENING
GLAUCOMA SCREENING
PUPILLOGRAPHY
IOL CALCULATION MODULE (optional)
INTRASTROMAL RINGS
CORNEAL ABERROMETRY
TECHNICAL DATA
Dimensions (HxDxW) | 515 x 315 x 255mm |
Weight | 7Kg |
Chin rest movement | 70mm ± 1mm |
Minimum height of the chin cup from table | 24cm |
Base movement (xyz) | 105 x 110 x 30mm |
Working distance | 74mm |
LIGHT SOURCES | |
Placido disk | LED @400-700nm |
Scheimpflug | LED @475nm UV-free |
Pupillography | LED @940nm |
Fluoresceine lighting | LED @470nm |
Auxiliary lighting | LED 400-700nm |
TOPOGRAPHY | |
Placido disk rings | 22 |
Measured points | Up to 151200 (front surface) and up to 145600 (rear surface) |
Topographic covering | 12mm |
Dioptric measurement range | 1D to 100D |
Measurement accuracy | Class A according to the UNI EN ISO 19980-2012 |
Compatibility with standard | DICOM v3 (IHE integration profile EYECARE Workflow) |
ACCESSORIES | |
Light diffuser filter for auxiliary illumination | magnetic light diffuser filter |
Yellow barrier filter | magnetic 530 nm filter |
Additional lens | magnetic -6D lens |
Calibration tool | r 8 mm calibration tool |
MINIMUM SYSTEM REQUIREMENT | |
PC: CPU: I3 or higher ( suggested I5) - CHIP SET: intel - RAM: 4 Gbyte or higher (suggested 8 Gbyte) -
|
To contact Eyetek about CSO Sirius+ | Topographer & Tomographer use Get a quote.
Sirius+ combines placido disk topography with Scheimpflug tomography of the anterior segment providing information on pachymetry, elevation, curvature and dioptric power of both corneal surfaces over a diameter of 12 mm. All biometric measurements of the anterior chamber are calculated using up to 100 HR corneal sections. Measurement speed reduces the effect of eye movement producing a high quality accurate measurement.
In addition to the clinical diagnosis of the anterior segment the most common uses are: refractive and cataract surgery, an IOL calculation module is available.
Objective examinations provide an accurate measurement of pupil diameter in scotopic, mesopic and photopic conditions.
KERATOCONOUS SCREENING
GLAUCOMA SCREENING
PUPILLOGRAPHY
IOL CALCULATION MODULE (optional)
INTRASTROMAL RINGS
CORNEAL ABERROMETRY
TECHNICAL DATA
Dimensions (HxDxW) | 515 x 315 x 255mm |
Weight | 7Kg |
Chin rest movement | 70mm ± 1mm |
Minimum height of the chin cup from table | 24cm |
Base movement (xyz) | 105 x 110 x 30mm |
Working distance | 74mm |
LIGHT SOURCES | |
Placido disk | LED @400-700nm |
Scheimpflug | LED @475nm UV-free |
Pupillography | LED @940nm |
Fluoresceine lighting | LED @470nm |
Auxiliary lighting | LED 400-700nm |
TOPOGRAPHY | |
Placido disk rings | 22 |
Measured points | Up to 151200 (front surface) and up to 145600 (rear surface) |
Topographic covering | 12mm |
Dioptric measurement range | 1D to 100D |
Measurement accuracy | Class A according to the UNI EN ISO 19980-2012 |
Compatibility with standard | DICOM v3 (IHE integration profile EYECARE Workflow) |
ACCESSORIES | |
Light diffuser filter for auxiliary illumination | magnetic light diffuser filter |
Yellow barrier filter | magnetic 530 nm filter |
Additional lens | magnetic -6D lens |
Calibration tool | r 8 mm calibration tool |
MINIMUM SYSTEM REQUIREMENT | |
PC: CPU: I3 or higher ( suggested I5) - CHIP SET: intel - RAM: 4 Gbyte or higher (suggested 8 Gbyte) -
|
To contact Eyetek about CSO Sirius+ | Topographer & Tomographer use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.