Epsilon Radioactive Sources - Siemens ...
Line Sources – Siemens
Ge-68 line sources are double layered tubes and made of high quality stainless steel. Each line source is sealed on its ends by the process of precise argon welding. Thanks to the argon welding process, the possibility of activity leakage is eliminated, ensuring safe use of line sources.
Source related information including product code, isotope type, activity, serial number and production date is permanently marked with laser for traceability.
Uniformity
Each line source is tested with 5 mm steps of scannings throughout its length for uniformity.
The uniformity of the line sources is within +/- 5% limits.
GE-68 Cylindirical Phantom – Siemens
Ge-68 Cylindirical phantoms are used for 2D and 3D normalization and in test images of PET and PET-CT systems. Radioactive element is uniformly filled in the cylindrical cast. Each cylindrical phantom manufactured is checked with a PET-CT scanner to ensure high quality.
The results of quality control image files are available upon request.
Uniformity Each line source is tested with 5 mm steps of scannings throughout its length for uniformity. The uniformity of the line sources is within +/- 5% limits.
To contact InMed Healthcare about Epsilon Radioactive Sources - Siemens PET/CT use Get a quote.
Line Sources – Siemens
Ge-68 line sources are double layered tubes and made of high quality stainless steel. Each line source is sealed on its ends by the process of precise argon welding. Thanks to the argon welding process, the possibility of activity leakage is eliminated, ensuring safe use of line sources.
Source related information including product code, isotope type, activity, serial number and production date is permanently marked with laser for traceability.
Uniformity
Each line source is tested with 5 mm steps of scannings throughout its length for uniformity.
The uniformity of the line sources is within +/- 5% limits.
GE-68 Cylindirical Phantom – Siemens
Ge-68 Cylindirical phantoms are used for 2D and 3D normalization and in test images of PET and PET-CT systems. Radioactive element is uniformly filled in the cylindrical cast. Each cylindrical phantom manufactured is checked with a PET-CT scanner to ensure high quality.
The results of quality control image files are available upon request.
Uniformity Each line source is tested with 5 mm steps of scannings throughout its length for uniformity. The uniformity of the line sources is within +/- 5% limits.
To contact InMed Healthcare about Epsilon Radioactive Sources - Siemens PET/CT use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product