Atomtex X-ray Radiation Dosimeter | ...
The Atomtex AT1103M is a highly-sensitive device which monitors for low-energy, low-intensity X-ray radiation exposure from devices such as video display units, night vision devices, oscillographs, TV receivers, microwave emitters, ion implanters, search and medical continuous X-ray apparatus.
A NaI(Tl) ø9×2 mm scintillator with beryllium window is used in the dosimeter as an X-ray detector. The Atomtex AT1103M measures directed dose equivalent rate of continuous X-ray radiation with energy from 5 keV.
Features
Specifications
Directional radiation dose equivalent rate measurement range | 50 nSv/h ... 100 µSv/h |
Directional radiation dose equivalent measurement range | 50 nSv ... 5 mSv |
Intrinsic relative measurement error | ±15% max |
Registered X-ray radiation energy range | 5 ... 160 keV |
Sensitivity for 241Am | 400 cps/µSv?h-1 |
Calibration error for 241Am | ±5% max |
Response time for dose rate change from 1 to 10 µSv/h | ≤2 s (accuracy error ≤±10%) |
Detectable 241Am activity at 0.5 m distance for period <2 s | 1000kBq (27 µCi) |
Energy dependence relative to241Am
5 keV ... 60 keV | ±35% |
60 keV ... 160 keV | ±30% |
To contact Nuclear Australia about Atomtex X-ray Radiation Dosimeter | Radiation Monitor | AT1103M use Get a quote.
The Atomtex AT1103M is a highly-sensitive device which monitors for low-energy, low-intensity X-ray radiation exposure from devices such as video display units, night vision devices, oscillographs, TV receivers, microwave emitters, ion implanters, search and medical continuous X-ray apparatus.
A NaI(Tl) ø9×2 mm scintillator with beryllium window is used in the dosimeter as an X-ray detector. The Atomtex AT1103M measures directed dose equivalent rate of continuous X-ray radiation with energy from 5 keV.
Features
Specifications
Directional radiation dose equivalent rate measurement range | 50 nSv/h ... 100 µSv/h |
Directional radiation dose equivalent measurement range | 50 nSv ... 5 mSv |
Intrinsic relative measurement error | ±15% max |
Registered X-ray radiation energy range | 5 ... 160 keV |
Sensitivity for 241Am | 400 cps/µSv?h-1 |
Calibration error for 241Am | ±5% max |
Response time for dose rate change from 1 to 10 µSv/h | ≤2 s (accuracy error ≤±10%) |
Detectable 241Am activity at 0.5 m distance for period <2 s | 1000kBq (27 µCi) |
Energy dependence relative to241Am
5 keV ... 60 keV | ±35% |
60 keV ... 160 keV | ±30% |
To contact Nuclear Australia about Atomtex X-ray Radiation Dosimeter | Radiation Monitor | AT1103M use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product