Raysafe Radiation Survey Meter - Raysafe ...
The RaySafe 452 Survey Meter is used for radiation measurements, and is compliant with IEC 60846-1. It has high sensitivity combined with a wide and flat energy response making it suitable for a broad range of medical and industrial radiation applications.
RaySafe 452 does not require any corrections or manual settings, letting you focus on radiation protection rather than setup. Just turn on the instrument and within a few seconds, you are ready to measure.
One device for every situation means less to carry, learn and handle. That equals less expense, more efficiency and time savings.
The RaySafe 452 Radiation Survey Meter can be used for many applications including these:
Broad range of applications
The ability to measure alpha, beta, gamma, and X-ray radiation, combined with excellent performance over a wide energy range, makes RaySafe 452 suitable for X-ray tube leakage, scattered and environmental radiation detection, non-destructive testing, and more. It measures ambient dose equivalent, air kerma and counts, all in one device.
Fast response time and automatic data storage
The proven technology utilizing silicon diodes combined with an energy compensated Geiger-Muller tube provides high sensitivity and stability over a very wide energy and dose rate range. The dose sensitive thin-walled Geiger-Muller tube enables a fast response time even at very low dose rates while the silicon diodes provide accuracy and speed at higher dose rates. The dose rate value is automatically saved every second providing comfort not to lose data.
Data analysis and reporting
RaySafe View, the included PC software, provides easy data transfer for further analysis and reporting. This software also supports settings of alarm threshold values.
Easy handling
The intuitive interface shows all parameters in one view. The integrated handle and display are positioned so you are able to see readings at all times. Navigation buttons are within easy reach of your thumb when holding the device.
Built for indoor and outdoor usage
Featuring a durable design, a wide temperature range, and IP64 classification ( (dust-proof and water resistant), makes indoor and outdoor measurements possible without worrying about the instrument. RaySafe 452 can also without any problems be wiped with a wet cloth or washed under rinsing water.
Excellent measurement performance over a broad energy range
Most survey meters do not handle all photon energies equally well. Instruments may either overestimate or underestimate the rate at certain energy levels. Unlike similar instruments, The RaySafe 452 design handles a wide range of applications and energies providing:
These are important features since adjustments using correction factors are hard to make due to the spread of photon energies within the radiation beam. Unlike for many other survey meters, no measurement adjustments are needed when using a RaySafe 452.
To contact InMed Healthcare about Raysafe Radiation Survey Meter - Raysafe 452 use Get a quote.
The RaySafe 452 Survey Meter is used for radiation measurements, and is compliant with IEC 60846-1. It has high sensitivity combined with a wide and flat energy response making it suitable for a broad range of medical and industrial radiation applications.
RaySafe 452 does not require any corrections or manual settings, letting you focus on radiation protection rather than setup. Just turn on the instrument and within a few seconds, you are ready to measure.
One device for every situation means less to carry, learn and handle. That equals less expense, more efficiency and time savings.
The RaySafe 452 Radiation Survey Meter can be used for many applications including these:
Broad range of applications
The ability to measure alpha, beta, gamma, and X-ray radiation, combined with excellent performance over a wide energy range, makes RaySafe 452 suitable for X-ray tube leakage, scattered and environmental radiation detection, non-destructive testing, and more. It measures ambient dose equivalent, air kerma and counts, all in one device.
Fast response time and automatic data storage
The proven technology utilizing silicon diodes combined with an energy compensated Geiger-Muller tube provides high sensitivity and stability over a very wide energy and dose rate range. The dose sensitive thin-walled Geiger-Muller tube enables a fast response time even at very low dose rates while the silicon diodes provide accuracy and speed at higher dose rates. The dose rate value is automatically saved every second providing comfort not to lose data.
Data analysis and reporting
RaySafe View, the included PC software, provides easy data transfer for further analysis and reporting. This software also supports settings of alarm threshold values.
Easy handling
The intuitive interface shows all parameters in one view. The integrated handle and display are positioned so you are able to see readings at all times. Navigation buttons are within easy reach of your thumb when holding the device.
Built for indoor and outdoor usage
Featuring a durable design, a wide temperature range, and IP64 classification ( (dust-proof and water resistant), makes indoor and outdoor measurements possible without worrying about the instrument. RaySafe 452 can also without any problems be wiped with a wet cloth or washed under rinsing water.
Excellent measurement performance over a broad energy range
Most survey meters do not handle all photon energies equally well. Instruments may either overestimate or underestimate the rate at certain energy levels. Unlike similar instruments, The RaySafe 452 design handles a wide range of applications and energies providing:
These are important features since adjustments using correction factors are hard to make due to the spread of photon energies within the radiation beam. Unlike for many other survey meters, no measurement adjustments are needed when using a RaySafe 452.
To contact InMed Healthcare about Raysafe Radiation Survey Meter - Raysafe 452 use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product