Nucleic Acid Purification | QIAscout
Whether you are performing single-cell sequencing, whole genome and transcriptome amplification or single-cell miRNA analysis; all you need to get started is your cell sample, the QIAscout device and an inverted microscope. The single cells isolated with the QIAscout can be combined with QIAGEN’s single-cell kits for your direct analysis or used for clonal expansion.
QIAscout Features:
QIAscout Procedure:
QIAscout Specifications:
Features
|
Specifications
|
Altitude | Up to 2000 m (6500 ft) |
Applications | Single-cell isolation |
Connections | Connect motor cable connector of the release device onto the controller until a snap-click sound is heard. To disconnect the motor cable, hold on to the connector and pull out the cable. |
Consumables (supplied) | QIAscout array with dimensions of 0.2 mm x 0.2 mm for each microraft. |
Controls | Controller; Input voltage: 12 VDC; Power: 6 W; Width: 94 mm (3.7 in); Depth: 132 mm (5.2 in.); Height: 46 mm (1.8 in.); Weight: 0.3 kg (0.66 lb) |
Description | Manual isolation of cells from a unique array on a petri-dish. Manual selection of microraft followed by piercing of microraft, collection of dislodged microraft and transfer to secondary vessel. |
Dimensions | Magnetic Wand; Size: Ø8 mm (0.3in.); Height: 55 mm (2.2in.); Magnetic Collection Plate; Width: 100 mm (5.9 in); Depth: 150 mm (3.9 in.); Height: 19 mm (0.7 in.); Release Device; Width: 44 mm (1.7 in.); Depth: 73 mm (2.9 in.); Height: 51 mm (2.0 in.); Release Needle Size; Diameter: 0.1 mm in the body; Diameter: 0.01 mm at the needle tip |
Environmental class | 3K2 (IEC 60721-3-3); 3M2 (IEC 60721-3-3) |
Operating temperature | 18–30ºC (64–86ºF) |
Overvoltage category | II |
Place of operation | For indoor use only |
Pollution degree | 2 |
Power supply | AC Power Adapter; Width: 39 mm (1.5 in); Depth: 76 mm (3.0 in.); Height: 56 mm (2.2 in.); Weight: 140 g (0.31 lb); Input Voltage: 100–240 VAC; Mains supply voltage fluctuations are not to exceed ±10% of the nominal supply voltages; Input Current: 0.45–0.2 A; Frequency: 50–60 Hz |
Relative humidity | 10–80% (noncondensing) |
Storage conditions | Air temperature: 5°C to 40°C (41°F to 104°F) in manufacturer’s packaging; Relative humidity: Max. 85% (noncondensing); Environmental class: 1K2 (IEC 60721-3-1); 1M2 (IEC 60721-3-1) |
Technical data of the instrument | Device temperature: 30°C ± 10°C; Motor connection: Snap and lock connector; Insertion force: 4.5 kgs max.; Withdrawer force: 0.5–3.0 kg; Motor actuator speed: 400 steps/sec; Dislodging action: 1 needle with moving platform |
Transportation conditions | Air temperature: –25ºC to 60ºC (–13°F to 140°F) in manufacturer’s packaging; Relative humidity: Max. 75% (noncondensing); Environmental class: 2K2 (IEC 60721-3-2); 2M2 (IEC 60721-3-2) |
Weight | Magnetic Wand: 2.2 g (0.005 lb); Magnetic Collection Plate: 0.3 kg (0.66 lb); Release Device: 0.2 kg (0.44lb) |
To contact QIagen Chadstone about Nucleic Acid Purification | QIAscout use Get a quote.
Whether you are performing single-cell sequencing, whole genome and transcriptome amplification or single-cell miRNA analysis; all you need to get started is your cell sample, the QIAscout device and an inverted microscope. The single cells isolated with the QIAscout can be combined with QIAGEN’s single-cell kits for your direct analysis or used for clonal expansion.
QIAscout Features:
QIAscout Procedure:
QIAscout Specifications:
Features
|
Specifications
|
Altitude | Up to 2000 m (6500 ft) |
Applications | Single-cell isolation |
Connections | Connect motor cable connector of the release device onto the controller until a snap-click sound is heard. To disconnect the motor cable, hold on to the connector and pull out the cable. |
Consumables (supplied) | QIAscout array with dimensions of 0.2 mm x 0.2 mm for each microraft. |
Controls | Controller; Input voltage: 12 VDC; Power: 6 W; Width: 94 mm (3.7 in); Depth: 132 mm (5.2 in.); Height: 46 mm (1.8 in.); Weight: 0.3 kg (0.66 lb) |
Description | Manual isolation of cells from a unique array on a petri-dish. Manual selection of microraft followed by piercing of microraft, collection of dislodged microraft and transfer to secondary vessel. |
Dimensions | Magnetic Wand; Size: Ø8 mm (0.3in.); Height: 55 mm (2.2in.); Magnetic Collection Plate; Width: 100 mm (5.9 in); Depth: 150 mm (3.9 in.); Height: 19 mm (0.7 in.); Release Device; Width: 44 mm (1.7 in.); Depth: 73 mm (2.9 in.); Height: 51 mm (2.0 in.); Release Needle Size; Diameter: 0.1 mm in the body; Diameter: 0.01 mm at the needle tip |
Environmental class | 3K2 (IEC 60721-3-3); 3M2 (IEC 60721-3-3) |
Operating temperature | 18–30ºC (64–86ºF) |
Overvoltage category | II |
Place of operation | For indoor use only |
Pollution degree | 2 |
Power supply | AC Power Adapter; Width: 39 mm (1.5 in); Depth: 76 mm (3.0 in.); Height: 56 mm (2.2 in.); Weight: 140 g (0.31 lb); Input Voltage: 100–240 VAC; Mains supply voltage fluctuations are not to exceed ±10% of the nominal supply voltages; Input Current: 0.45–0.2 A; Frequency: 50–60 Hz |
Relative humidity | 10–80% (noncondensing) |
Storage conditions | Air temperature: 5°C to 40°C (41°F to 104°F) in manufacturer’s packaging; Relative humidity: Max. 85% (noncondensing); Environmental class: 1K2 (IEC 60721-3-1); 1M2 (IEC 60721-3-1) |
Technical data of the instrument | Device temperature: 30°C ± 10°C; Motor connection: Snap and lock connector; Insertion force: 4.5 kgs max.; Withdrawer force: 0.5–3.0 kg; Motor actuator speed: 400 steps/sec; Dislodging action: 1 needle with moving platform |
Transportation conditions | Air temperature: –25ºC to 60ºC (–13°F to 140°F) in manufacturer’s packaging; Relative humidity: Max. 75% (noncondensing); Environmental class: 2K2 (IEC 60721-3-2); 2M2 (IEC 60721-3-2) |
Weight | Magnetic Wand: 2.2 g (0.005 lb); Magnetic Collection Plate: 0.3 kg (0.66 lb); Release Device: 0.2 kg (0.44lb) |
To contact QIagen Chadstone about Nucleic Acid Purification | QIAscout use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.