UT101B model designed for safe, simple and controllable inhalation anesthesia for animals.The Veterinary Anesthesia System provides rapid control of anesthetic depth with little resistance to respiration from high to low acuity,simple to complex cases, small to big animals,like Dogs, Cats, Rabbits, Mice, Birds, etc.
Trust Point
Safety
Advantage
Ventilation mode: | IPPV, A/C, SIMV, SIGH, MANUAL |
Ventilator parameter range | |
Flowmeter | O2 (0.1~10L/min) |
Rapid oxygen supply | 25L/min~75L/min |
Tidal volume (Vt) | 0, 20 mL ~ 1500 mL |
Frequence(Freq) | 1/min~100/min |
I:E | 2:1~1:6 |
Pressure triggering sensitivity (Ptr) | -20 cmH2O~0 cmH2O(Based on PEEP) |
Flow trigger sensitivity (Ftr) | 0.5 L/min ~ 30 L/min |
SIGH | 0(off) 1/100 ~ 5/100 |
Apnea ventilation | OFF, 5 s ~ 60 s |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitoring Parameters | |
Frequence(Freq) | 0 /min ~ 100 /min |
Tidal volume (Vt) | 0 mL ~ 2000 mL |
MV | 0 L/min ~ 100 L/min |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for back up battery | < 11.3±0.3V |
No tidal volume | ≤5mL within 6s |
High oxygen concentration alarm | 19%-100% |
Low oxygen concentration alarm | 0%-19% |
High airway pressure alarm | 20cmH2O-100cmH2O |
Low airway pressure alarm | 0cmH2O-20cmH2O |
High minute volume alarm | 5L/min-20L/min |
Low minute volume alarm | 1L/min-15L/min (0-10L/min) |
Continuous pressure alarm | (PEEP+1.5kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | < 12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Working condition | |
Air source | O2 |
Air pressure | 280 kPa ~ 600 kPa |
Power supply | 100-240V~ |
Frequency | 50 /60HZ |
DM6B anesthesia system includes the following monitoring devices ,alarm devices and
protection devices:
To contact Utech Medical Device Pty Ltd about DM6B Veterinary Anesthesia System use Get a quote.
UT101B model designed for safe, simple and controllable inhalation anesthesia for animals.The Veterinary Anesthesia System provides rapid control of anesthetic depth with little resistance to respiration from high to low acuity,simple to complex cases, small to big animals,like Dogs, Cats, Rabbits, Mice, Birds, etc.
Trust Point
Safety
Advantage
Ventilation mode: | IPPV, A/C, SIMV, SIGH, MANUAL |
Ventilator parameter range | |
Flowmeter | O2 (0.1~10L/min) |
Rapid oxygen supply | 25L/min~75L/min |
Tidal volume (Vt) | 0, 20 mL ~ 1500 mL |
Frequence(Freq) | 1/min~100/min |
I:E | 2:1~1:6 |
Pressure triggering sensitivity (Ptr) | -20 cmH2O~0 cmH2O(Based on PEEP) |
Flow trigger sensitivity (Ftr) | 0.5 L/min ~ 30 L/min |
SIGH | 0(off) 1/100 ~ 5/100 |
Apnea ventilation | OFF, 5 s ~ 60 s |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitoring Parameters | |
Frequence(Freq) | 0 /min ~ 100 /min |
Tidal volume (Vt) | 0 mL ~ 2000 mL |
MV | 0 L/min ~ 100 L/min |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for back up battery | < 11.3±0.3V |
No tidal volume | ≤5mL within 6s |
High oxygen concentration alarm | 19%-100% |
Low oxygen concentration alarm | 0%-19% |
High airway pressure alarm | 20cmH2O-100cmH2O |
Low airway pressure alarm | 0cmH2O-20cmH2O |
High minute volume alarm | 5L/min-20L/min |
Low minute volume alarm | 1L/min-15L/min (0-10L/min) |
Continuous pressure alarm | (PEEP+1.5kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | < 12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Working condition | |
Air source | O2 |
Air pressure | 280 kPa ~ 600 kPa |
Power supply | 100-240V~ |
Frequency | 50 /60HZ |