UTMD VS2000VCS 7" Veterinary Vital Signs ...
Production Description:
The VS2000V Veterinary vital signs monitor is a Multi-parameter monitor. It is with parameters of SPO2, ECG, NIBP, PR, RESP, TEMP, and ETCO2. It is highly compact and portable to carry out. Also it is providing fast and reliable measurements for the veterinary patients. The measuring size of patients animals range from the small to big animals such as cats dogs, horses. It is suitable for vet hospital, clinic, and animal labs.
VS2000V passed the CE certification. It has been sold to more than 30 countries such as the United States, Korea, and Colombia and so on. Both retailers and veterinarian are satisfied with our products in terms of quality, price and prompt after-sales service.
Main Features:
Central Monitoring Software
Mobile Trolley
Carrying Bag
Main unit 2 years
Accessories 6 months
Technical Specification | |||||
Enclosure | |||||
Weight | 2.05 kg (4.52lbs) | ||||
Dimensions | 32.4cm × 12.9cm × 18.3cm | ||||
Display | 7.1-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD 800 X 480 | ||||
Alarms | |||||
Categories | Patient status and system status | ||||
Notification | Audible and visual | ||||
Setting | Full storage, low battery and sensor off | ||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%), NIBP (0-300mmHg), RESP (5-150rpm), TEMP (24.5-45.5?) | ||||
Alarm volume level | 45dBA to 85 dBA at 1 meter distance (adjustable) | ||||
Range, Accuracy and Resolution | |||||
Range Type | Range Values | ||||
Measurement Ranges | |||||
SpO2 | 0-100% | ||||
Pulse rate | 30-350bpm | ||||
NIBP | Systolic:40 to 270 mmHg Mean Arterial:30 to 220 mmHg Diastolic:20 to 200 mmHg |
||||
RESP | 0-150rpm | ||||
TEMP | 0-50? | ||||
Measurement Accuracy | |||||
SpO2 | 70-100% (±2%), <70% undefined | ||||
Pulse rate | ±2bpm/±2% take maximum | ||||
ETCO2 | 0~40mmHg ±2mmHg, 41~150mmHg ±10% | ||||
TEMP | ±0.2? | ||||
RESP | ±1rpm | ||||
Resolution | |||||
Display | 800 X 480 | ||||
SpO2 | 1% | ||||
ETCO2 | 0.1mmHg | ||||
TEMP | 0.1? | ||||
RESP | 1rpm | ||||
Pulse rate | 1bpm | ||||
Electrical | |||||
AC power requirement | 100-240VA, 50/60Hz | ||||
Power comsumption | 60VA,FUSE T1.5A | ||||
Batteries | |||||
Types | Lithium-lon Batteries | ||||
Operating time | ≥4hours | ||||
Charge time | ≤4hours | ||||
Environment | |||||
Operating tempearture | 0-50? | ||||
Storage temperature | -40-75? | ||||
Operating humidity | 15-95% | ||||
Storage humidity | 10-95% | ||||
Operating altitude | -500-5000m | ||||
Standards and Certification | |||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | ||||
IEC 62304 | Medical device-software life cycle processes | ||||
MDD 93/42/EEC | European Medical Device Directive | ||||
ISO 13485 | Medical equipment-Quality management system | ||||
EN ISO 14971 | Medical devices-Risk management | ||||
EN 60601-1 | Medical electrical equipment | ||||
EN 60601-2 | Medical electrical equipment | ||||
EN 60601-8 | Medical electrical equipment | ||||
EN 980 | Symbols for use in labeling of medical devices | ||||
EN 1041 | Information supplied by the manufacture of medical devices | ||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | ||||
EN ISO 10993-1 | Biological evaluation of medical devices | ||||
EN ISO 10993-5 | Biological evaluation of medical devices | ||||
EN ISO 10993-10 | Biological evaluation of medical devices | ||||
ISO 14155-1 | Clinical investigation of medical devices | ||||
CE | CONFORMITE EUROPEENNE | ||||
SFDA | State Food and Drug Administration |
To contact Utech Medical Device Pty Ltd about UTMD VS2000VCS 7" Veterinary Vital Signs Monitor - ECG SPO2 NIBP TEMP ETCO2 use Get a quote.
Production Description:
The VS2000V Veterinary vital signs monitor is a Multi-parameter monitor. It is with parameters of SPO2, ECG, NIBP, PR, RESP, TEMP, and ETCO2. It is highly compact and portable to carry out. Also it is providing fast and reliable measurements for the veterinary patients. The measuring size of patients animals range from the small to big animals such as cats dogs, horses. It is suitable for vet hospital, clinic, and animal labs.
VS2000V passed the CE certification. It has been sold to more than 30 countries such as the United States, Korea, and Colombia and so on. Both retailers and veterinarian are satisfied with our products in terms of quality, price and prompt after-sales service.
Main Features:
Central Monitoring Software
Mobile Trolley
Carrying Bag
Main unit 2 years
Accessories 6 months
Technical Specification | |||||
Enclosure | |||||
Weight | 2.05 kg (4.52lbs) | ||||
Dimensions | 32.4cm × 12.9cm × 18.3cm | ||||
Display | 7.1-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD 800 X 480 | ||||
Alarms | |||||
Categories | Patient status and system status | ||||
Notification | Audible and visual | ||||
Setting | Full storage, low battery and sensor off | ||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%), NIBP (0-300mmHg), RESP (5-150rpm), TEMP (24.5-45.5?) | ||||
Alarm volume level | 45dBA to 85 dBA at 1 meter distance (adjustable) | ||||
Range, Accuracy and Resolution | |||||
Range Type | Range Values | ||||
Measurement Ranges | |||||
SpO2 | 0-100% | ||||
Pulse rate | 30-350bpm | ||||
NIBP | Systolic:40 to 270 mmHg Mean Arterial:30 to 220 mmHg Diastolic:20 to 200 mmHg |
||||
RESP | 0-150rpm | ||||
TEMP | 0-50? | ||||
Measurement Accuracy | |||||
SpO2 | 70-100% (±2%), <70% undefined | ||||
Pulse rate | ±2bpm/±2% take maximum | ||||
ETCO2 | 0~40mmHg ±2mmHg, 41~150mmHg ±10% | ||||
TEMP | ±0.2? | ||||
RESP | ±1rpm | ||||
Resolution | |||||
Display | 800 X 480 | ||||
SpO2 | 1% | ||||
ETCO2 | 0.1mmHg | ||||
TEMP | 0.1? | ||||
RESP | 1rpm | ||||
Pulse rate | 1bpm | ||||
Electrical | |||||
AC power requirement | 100-240VA, 50/60Hz | ||||
Power comsumption | 60VA,FUSE T1.5A | ||||
Batteries | |||||
Types | Lithium-lon Batteries | ||||
Operating time | ≥4hours | ||||
Charge time | ≤4hours | ||||
Environment | |||||
Operating tempearture | 0-50? | ||||
Storage temperature | -40-75? | ||||
Operating humidity | 15-95% | ||||
Storage humidity | 10-95% | ||||
Operating altitude | -500-5000m | ||||
Standards and Certification | |||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | ||||
IEC 62304 | Medical device-software life cycle processes | ||||
MDD 93/42/EEC | European Medical Device Directive | ||||
ISO 13485 | Medical equipment-Quality management system | ||||
EN ISO 14971 | Medical devices-Risk management | ||||
EN 60601-1 | Medical electrical equipment | ||||
EN 60601-2 | Medical electrical equipment | ||||
EN 60601-8 | Medical electrical equipment | ||||
EN 980 | Symbols for use in labeling of medical devices | ||||
EN 1041 | Information supplied by the manufacture of medical devices | ||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | ||||
EN ISO 10993-1 | Biological evaluation of medical devices | ||||
EN ISO 10993-5 | Biological evaluation of medical devices | ||||
EN ISO 10993-10 | Biological evaluation of medical devices | ||||
ISO 14155-1 | Clinical investigation of medical devices | ||||
CE | CONFORMITE EUROPEENNE | ||||
SFDA | State Food and Drug Administration |