UTMD Veterinary Handheld Pulse Oximeters ...
Applications for this product
Features of this product
The UT100V Veterinary Pulse Oximeter is a low cost monitor for spot checking, continuous,non-invasive monitoring or recording of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate and pulse strength. It may be used in the veterinary hospital or clinical environment. The oximeter works with given sensors providing SpO2 and pulse rate on a variety of veterinaries like horses, dogs and cats etc with adjustable alarm limits as well as visible and audible alarm signals.
Why Choose This Product
Specifications of this product
Technical Specification | |||||
Enclosure | |||||
Weight | 258grams (9.1 ounces) with batteries | ||||
Dimensions | 13.5cm × 7.5cm × 2.8cm | ||||
Alarms | |||||
Categories | Patient status and system status | ||||
Notification | Audible and visual | ||||
Setting | Full storage, low battery and sensor off | ||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%) | ||||
Alarm volume level | 0-85dB | ||||
Range, Accuracy and Resolution | |||||
Range Type | Range Values | ||||
Measurement Ranges | |||||
SpO2 measuring range | 0-100% | ||||
Pulse rate range | 30-350bpm | ||||
Measurement Accuracy | |||||
SpO2 measuring accuracy | 70-100% (±2%), <70% undefined | ||||
Pulse rate measuring accuracy | ±2bpm/±2% take maximum | ||||
Resolution | |||||
SpO2 | 1% | ||||
Pulse rate | 1bpm | ||||
Electrical | |||||
AC power requirement | 100-240VA, 47-63Hz | ||||
Power comsumption | 20VA | ||||
Batteries | |||||
Types | Alkaline/Ni-Mh Batteries, IEC: LR6 | ||||
Operating time | =20hours | ||||
Charge time | = 6hours | ||||
Environment | |||||
Operating tempearture | 0-45? | ||||
Storage temperature | -20-60? | ||||
Operating humidity | 30-95% | ||||
Operating altitude | -500-5000m | ||||
Trends | |||||
Types | Tabular | ||||
Memory | Save total 120 hours data events. Save data and time, alarm conditions, pulse rate and SpO2 measurements | ||||
Standards and Certification | |||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | ||||
IEC 62304 | Medical device-software life cycle processes | ||||
MDD 93/42/EEC | European Medical Device Directive | ||||
ISO 13485 | Medical equipment-Quality management system | ||||
EN ISO 14971 | Medical devices-Risk management | ||||
EN 60601-1 | Medical electrical equipment | ||||
EN 60601-2 | Medical electrical equipment | ||||
EN 60601-8 | Medical electrical equipment | ||||
EN 980 | Symbols for use in labeling of medical devices | ||||
EN 1041 | Information supplied by the manufacture of medical devices | ||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | ||||
EN ISO 10993-1 | Biological evaluation of medical devices | ||||
EN ISO 10993-5 | Biological evaluation of medical devices | ||||
EN ISO 10993-10 | Biological evaluation of medical devices | ||||
ISO 14155-1 | Clinical investigation of medical devices | ||||
CE | CONFORMITE EUROPEENNE | ||||
SFDA | State Food and Drug Administration |
To contact Utech Medical Device Pty Ltd about UTMD Veterinary Handheld Pulse Oximeters - UT100V, with SPO2 PR RESP use Get a quote.
Applications for this product
Features of this product
The UT100V Veterinary Pulse Oximeter is a low cost monitor for spot checking, continuous,non-invasive monitoring or recording of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate and pulse strength. It may be used in the veterinary hospital or clinical environment. The oximeter works with given sensors providing SpO2 and pulse rate on a variety of veterinaries like horses, dogs and cats etc with adjustable alarm limits as well as visible and audible alarm signals.
Why Choose This Product
Specifications of this product
Technical Specification | |||||
Enclosure | |||||
Weight | 258grams (9.1 ounces) with batteries | ||||
Dimensions | 13.5cm × 7.5cm × 2.8cm | ||||
Alarms | |||||
Categories | Patient status and system status | ||||
Notification | Audible and visual | ||||
Setting | Full storage, low battery and sensor off | ||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%) | ||||
Alarm volume level | 0-85dB | ||||
Range, Accuracy and Resolution | |||||
Range Type | Range Values | ||||
Measurement Ranges | |||||
SpO2 measuring range | 0-100% | ||||
Pulse rate range | 30-350bpm | ||||
Measurement Accuracy | |||||
SpO2 measuring accuracy | 70-100% (±2%), <70% undefined | ||||
Pulse rate measuring accuracy | ±2bpm/±2% take maximum | ||||
Resolution | |||||
SpO2 | 1% | ||||
Pulse rate | 1bpm | ||||
Electrical | |||||
AC power requirement | 100-240VA, 47-63Hz | ||||
Power comsumption | 20VA | ||||
Batteries | |||||
Types | Alkaline/Ni-Mh Batteries, IEC: LR6 | ||||
Operating time | =20hours | ||||
Charge time | = 6hours | ||||
Environment | |||||
Operating tempearture | 0-45? | ||||
Storage temperature | -20-60? | ||||
Operating humidity | 30-95% | ||||
Operating altitude | -500-5000m | ||||
Trends | |||||
Types | Tabular | ||||
Memory | Save total 120 hours data events. Save data and time, alarm conditions, pulse rate and SpO2 measurements | ||||
Standards and Certification | |||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | ||||
IEC 62304 | Medical device-software life cycle processes | ||||
MDD 93/42/EEC | European Medical Device Directive | ||||
ISO 13485 | Medical equipment-Quality management system | ||||
EN ISO 14971 | Medical devices-Risk management | ||||
EN 60601-1 | Medical electrical equipment | ||||
EN 60601-2 | Medical electrical equipment | ||||
EN 60601-8 | Medical electrical equipment | ||||
EN 980 | Symbols for use in labeling of medical devices | ||||
EN 1041 | Information supplied by the manufacture of medical devices | ||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | ||||
EN ISO 10993-1 | Biological evaluation of medical devices | ||||
EN ISO 10993-5 | Biological evaluation of medical devices | ||||
EN ISO 10993-10 | Biological evaluation of medical devices | ||||
ISO 14155-1 | Clinical investigation of medical devices | ||||
CE | CONFORMITE EUROPEENNE | ||||
SFDA | State Food and Drug Administration |