UTMD Handheld Veterinary Capnography ...
Applications
Features
1. Small and light, ergonomically designed to fit comfortably in the palm of your hand
2. 2.8 inch large-sized colourful screen, bright, easy to read LCD displays indicate SpO2, ETCO2 and pulse rate measurements, plethysmogram and trend table
3. Screen rotation provides upright display for vertical or horizontal monitoring position
4. Perfusion index indicates arterial pulse signal strength
5. Two measuring modes:
Spot-check mode: measure data intermittently
Monitor mode: measure and store data continuously
6. Quick, reliable and accurate readings on SpO2, ETCO2 and Pulse rate
7. 120 hours record storage
8. Visual and audible alarm
9. Adjustable volume (including silence) "beep" sounds with each pulse beat
10. Expanded heart rate values and veterinary specific SpO2 sensors to accommodate a variety of species
11. Patient information management. Patient's information such as ID, Sex, Type can be edited
12. USB interface. Data can be transferred to PC through a data line for storage, review and analysis
13. Low power consumption, long operation time (more than 20 hours)
14. Uses 4 standard AA alkaline or Ni-MH Batteries
15. Low battery Alarm. Low battery icon flashes when about 15 minutes of battery use remains.
16. 4 display modes:
Big Display Mode
Waveform Display Mode
Trend-table Display Mode
Horizontal Display Mode
17. Multi-languages: English, French, Spanish, Germany, Chinese
18. AC power jack. An optional to connect to AC power supply
Standard Configuration
1. Veterinary Handheld UT100VC main unit
2. Veterinary SpO2 sensor (ear clip)
3. Mainstream ETCO2 Sensor
4. Big Airway Adapter
5. Small Airway Adapter
6. Adapter Cable
7. Hanging Strap
Optional Accessories:
1. Carrying Bag
2. ODMS (Oximetry Data Management System)
3. Ni-NH Rechargeable Cells/ Batteries
4. Alkaline Cells/ Batteries
Specifications
Enclosure | |||||
Weight | 258grams (9.1 ounces) with batteries | ||||
Dimensions | 13.5cm × 7.5cm × 2.8cm | ||||
Alarms | |||||
Categories | Patient status and system status | ||||
Notification | Audible and visual | ||||
Setting | Full storage, low battery and sensor off | ||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%) | ||||
Alarm volume level | 0-85dB | ||||
Range, Accuracy and Resolution | |||||
Range Type | Range Values | ||||
Measurement Ranges | |||||
SpO2 | 0-100% | ||||
Pulse rate | 30-350bpm | ||||
RESP | 0-150bpm | ||||
ETCO2 | 0-20% (0-150mmHg) | ||||
Measurement Accuracy | |||||
SpO2 | 70-100% (±2%), <70% undefined | ||||
Pulse rate | ±2bpm/±2% take maximum | ||||
ETCO2 | ±2 mm Hg @ < 5.0% CO2 (at BTPS) < 10% of reading @ > 5.0% CO2(at BTPS) |
||||
RESP | ±1rpm | ||||
Resolution | |||||
SpO2 | 1% | ||||
Pulse rate | 1bpm | ||||
ETCO2 | 0.1mmHg | ||||
RESP | 1rpm | ||||
Electrical | |||||
AC power requirement | 100-240VA, 47-63Hz | ||||
Power comsumption | 20VA | ||||
Batteries | |||||
Types | Alkaline/Ni-Mh Batteries, IEC: LR6 | ||||
Operating time | =20hours without ETCO2;=10hours with ETCO2 | ||||
Charge time | = 6hours | ||||
Environment | |||||
Operating tempearture | 0-45? | ||||
Storage temperature | -20-60? | ||||
Operating humidity | 30-95% | ||||
Operating altitude | -500-5000m | ||||
Trends | |||||
Types | Tabular | ||||
Memory | Save total 120 hours data events. Save data and time, alarm conditions, pulse rate and SpO2 measurements | ||||
Standards and Certification | |||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | ||||
IEC 62304 | Medical device-software life cycle processes | ||||
MDD 93/42/EEC | European Medical Device Directive | ||||
ISO 13485 | Medical equipment-Quality management system | ||||
EN ISO 14971 | Medical devices-Risk management | ||||
EN 60601-1 | Medical electrical equipment | ||||
EN 60601-2 | Medical electrical equipment | ||||
EN 60601-8 | Medical electrical equipment | ||||
EN 980 | Symbols for use in labeling of medical devices | ||||
EN 1041 | Information supplied by the manufacture of medical devices | ||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | ||||
EN ISO 10993-1 | Biological evaluation of medical devices | ||||
EN ISO 10993-5 | Biological evaluation of medical devices | ||||
EN ISO 10993-10 | Biological evaluation of medical devices | ||||
ISO 14155-1 | Clinical investigation of medical devices | ||||
CE | CONFORMITE EUROPEENNE | ||||
SFDA | State Food and Drug Administration |
Warranty:
Main Unit: 2 Years
Accessories: 6 Months
To contact Utech Medical Device Pty Ltd about UTMD Handheld Veterinary Capnography Monitor UT100VCM SPO2/MAINSTREAM ETCO2 use Get a quote.
Applications
Features
1. Small and light, ergonomically designed to fit comfortably in the palm of your hand
2. 2.8 inch large-sized colourful screen, bright, easy to read LCD displays indicate SpO2, ETCO2 and pulse rate measurements, plethysmogram and trend table
3. Screen rotation provides upright display for vertical or horizontal monitoring position
4. Perfusion index indicates arterial pulse signal strength
5. Two measuring modes:
Spot-check mode: measure data intermittently
Monitor mode: measure and store data continuously
6. Quick, reliable and accurate readings on SpO2, ETCO2 and Pulse rate
7. 120 hours record storage
8. Visual and audible alarm
9. Adjustable volume (including silence) "beep" sounds with each pulse beat
10. Expanded heart rate values and veterinary specific SpO2 sensors to accommodate a variety of species
11. Patient information management. Patient's information such as ID, Sex, Type can be edited
12. USB interface. Data can be transferred to PC through a data line for storage, review and analysis
13. Low power consumption, long operation time (more than 20 hours)
14. Uses 4 standard AA alkaline or Ni-MH Batteries
15. Low battery Alarm. Low battery icon flashes when about 15 minutes of battery use remains.
16. 4 display modes:
Big Display Mode
Waveform Display Mode
Trend-table Display Mode
Horizontal Display Mode
17. Multi-languages: English, French, Spanish, Germany, Chinese
18. AC power jack. An optional to connect to AC power supply
Standard Configuration
1. Veterinary Handheld UT100VC main unit
2. Veterinary SpO2 sensor (ear clip)
3. Mainstream ETCO2 Sensor
4. Big Airway Adapter
5. Small Airway Adapter
6. Adapter Cable
7. Hanging Strap
Optional Accessories:
1. Carrying Bag
2. ODMS (Oximetry Data Management System)
3. Ni-NH Rechargeable Cells/ Batteries
4. Alkaline Cells/ Batteries
Specifications
Enclosure | |||||
Weight | 258grams (9.1 ounces) with batteries | ||||
Dimensions | 13.5cm × 7.5cm × 2.8cm | ||||
Alarms | |||||
Categories | Patient status and system status | ||||
Notification | Audible and visual | ||||
Setting | Full storage, low battery and sensor off | ||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%) | ||||
Alarm volume level | 0-85dB | ||||
Range, Accuracy and Resolution | |||||
Range Type | Range Values | ||||
Measurement Ranges | |||||
SpO2 | 0-100% | ||||
Pulse rate | 30-350bpm | ||||
RESP | 0-150bpm | ||||
ETCO2 | 0-20% (0-150mmHg) | ||||
Measurement Accuracy | |||||
SpO2 | 70-100% (±2%), <70% undefined | ||||
Pulse rate | ±2bpm/±2% take maximum | ||||
ETCO2 | ±2 mm Hg @ < 5.0% CO2 (at BTPS) < 10% of reading @ > 5.0% CO2(at BTPS) |
||||
RESP | ±1rpm | ||||
Resolution | |||||
SpO2 | 1% | ||||
Pulse rate | 1bpm | ||||
ETCO2 | 0.1mmHg | ||||
RESP | 1rpm | ||||
Electrical | |||||
AC power requirement | 100-240VA, 47-63Hz | ||||
Power comsumption | 20VA | ||||
Batteries | |||||
Types | Alkaline/Ni-Mh Batteries, IEC: LR6 | ||||
Operating time | =20hours without ETCO2;=10hours with ETCO2 | ||||
Charge time | = 6hours | ||||
Environment | |||||
Operating tempearture | 0-45? | ||||
Storage temperature | -20-60? | ||||
Operating humidity | 30-95% | ||||
Operating altitude | -500-5000m | ||||
Trends | |||||
Types | Tabular | ||||
Memory | Save total 120 hours data events. Save data and time, alarm conditions, pulse rate and SpO2 measurements | ||||
Standards and Certification | |||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | ||||
IEC 62304 | Medical device-software life cycle processes | ||||
MDD 93/42/EEC | European Medical Device Directive | ||||
ISO 13485 | Medical equipment-Quality management system | ||||
EN ISO 14971 | Medical devices-Risk management | ||||
EN 60601-1 | Medical electrical equipment | ||||
EN 60601-2 | Medical electrical equipment | ||||
EN 60601-8 | Medical electrical equipment | ||||
EN 980 | Symbols for use in labeling of medical devices | ||||
EN 1041 | Information supplied by the manufacture of medical devices | ||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | ||||
EN ISO 10993-1 | Biological evaluation of medical devices | ||||
EN ISO 10993-5 | Biological evaluation of medical devices | ||||
EN ISO 10993-10 | Biological evaluation of medical devices | ||||
ISO 14155-1 | Clinical investigation of medical devices | ||||
CE | CONFORMITE EUROPEENNE | ||||
SFDA | State Food and Drug Administration |
Warranty:
Main Unit: 2 Years
Accessories: 6 Months