UTMD 12" Multiparameters Veterinary Patient ...
12.1' coloured and bright, high definition (800 x 600) TFT LCD screen;
Parameters: SpO2, ECG, Heart Rate,NIBP, TEMP*2, RESP (Optional: Sidestream ETCO2, IBP);
Suitable for cats, dogs, horses and other animals;
72 hours graphic and tabular trends of all parameters;
32 seconds full-disclosure waveform review ;
500 NIBP and SpO2 measurement data can be stored and recalled;
Dual Batteries for long time continuous operation
100M Base-T Ethernet Interface, Support to connect to IPMS8000 Patient Management System;
Special designed SpO2 technology with adjustable emitting light and a wide range measurement for veterinary
Special designed ECG technology with high input impedance to suit for different size of veterinaries
Special designed NIBP technology with different size of NIBP cuffs for veterinaries
Sidestream technology accommodates intubated and non-intubated animals
Unique Designed LOGO for veterinary use only
Ergonomically designed handle to fit your hand comfortably
Can link with IPMS8000 intelligent patient monitor system
Multi-language: English, Chinese, French, Spanish, Germany
Technical Specification | |||||
Enclosure | |||||
Weight | 2.05 kg (4.52lbs) | ||||
Dimensions | 32.4cm × 32.4cm × 18.3cm | ||||
Display | 7.1-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD 800 X 480 | ||||
Alarms | |||||
Categories | Patient status and system status | ||||
Notification | Audible and visual | ||||
Setting | Full storage, low battery and sensor off | ||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%), NIBP (0-300mmHg), RESP (5-150rpm), TEMP (24.5-45.5?) | ||||
Alarm volume level | 45dBA to 85 dBA at 1 meter distance (adjustable) | ||||
Range, Accuracy and Resolution | |||||
Range Type | Range Values | ||||
Measurement Ranges | |||||
SpO2 | 0-100% | ||||
Pulse rate | 30-350bpm | ||||
NIBP | Systolic:40 to 270 mmHg Mean Arterial:30 to 220 mmHg Diastolic:20 to 200 mmHg |
||||
RESP | 0-150rpm | ||||
TEMP | 0-50? | ||||
Measurement Accuracy | |||||
SpO2 | 70-100% (±2%), <70% undefined | ||||
Pulse rate | ±2bpm/±2% take maximum | ||||
ETCO2 | 0~40mmHg ±2mmHg, 41~150mmHg ±10% | ||||
TEMP | ±0.2? | ||||
RESP | ±1rpm | ||||
Resolution | |||||
Display | 800 X 480 | ||||
SpO2 | 1% | ||||
ETCO2 | 0.1mmHg | ||||
TEMP | 0.1? | ||||
RESP | 1rpm | ||||
Pulse rate | 1bpm | ||||
Electrical | |||||
AC power requirement | 100-240VA, 50/60Hz | ||||
Power comsumption | 60VA,FUSE T1.5A | ||||
Batteries | |||||
Types | Lithium-lon Batteries | ||||
Operating time | ≥4hours | ||||
Charge time | ≤4hours | ||||
Environment | |||||
Operating tempearture | 0-50? | ||||
Storage temperature | -40-75? | ||||
Operating humidity | 15-95% | ||||
Storage humidity | 10-95% | ||||
Operating altitude | -500-5000m | ||||
Standards and Certification | |||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | ||||
IEC 62304 | Medical device-software life cycle processes | ||||
MDD 93/42/EEC | European Medical Device Directive | ||||
ISO 13485 | Medical equipment-Quality management system | ||||
EN ISO 14971 | Medical devices-Risk management | ||||
EN 60601-1 | Medical electrical equipment | ||||
EN 60601-2 | Medical electrical equipment | ||||
EN 60601-8 | Medical electrical equipment | ||||
EN 980 | Symbols for use in labeling of medical devices | ||||
EN 1041 | Information supplied by the manufacture of medical devices | ||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | ||||
EN ISO 10993-1 | Biological evaluation of medical devices | ||||
EN ISO 10993-5 | Biological evaluation of medical devices | ||||
EN ISO 10993-10 | Biological evaluation of medical devices | ||||
ISO 14155-1 | Clinical investigation of medical devices | ||||
CE | CONFORMITE EUROPEENNE | ||||
SFDA | State Food and Drug Administration |
To contact Utech Medical Device Pty Ltd about UTMD 12" Multiparameters Veterinary Patient Monitor with ECG Resp | PM6000P use Get a quote.
12.1' coloured and bright, high definition (800 x 600) TFT LCD screen;
Parameters: SpO2, ECG, Heart Rate,NIBP, TEMP*2, RESP (Optional: Sidestream ETCO2, IBP);
Suitable for cats, dogs, horses and other animals;
72 hours graphic and tabular trends of all parameters;
32 seconds full-disclosure waveform review ;
500 NIBP and SpO2 measurement data can be stored and recalled;
Dual Batteries for long time continuous operation
100M Base-T Ethernet Interface, Support to connect to IPMS8000 Patient Management System;
Special designed SpO2 technology with adjustable emitting light and a wide range measurement for veterinary
Special designed ECG technology with high input impedance to suit for different size of veterinaries
Special designed NIBP technology with different size of NIBP cuffs for veterinaries
Sidestream technology accommodates intubated and non-intubated animals
Unique Designed LOGO for veterinary use only
Ergonomically designed handle to fit your hand comfortably
Can link with IPMS8000 intelligent patient monitor system
Multi-language: English, Chinese, French, Spanish, Germany
Technical Specification | |||||
Enclosure | |||||
Weight | 2.05 kg (4.52lbs) | ||||
Dimensions | 32.4cm × 32.4cm × 18.3cm | ||||
Display | 7.1-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD 800 X 480 | ||||
Alarms | |||||
Categories | Patient status and system status | ||||
Notification | Audible and visual | ||||
Setting | Full storage, low battery and sensor off | ||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%), NIBP (0-300mmHg), RESP (5-150rpm), TEMP (24.5-45.5?) | ||||
Alarm volume level | 45dBA to 85 dBA at 1 meter distance (adjustable) | ||||
Range, Accuracy and Resolution | |||||
Range Type | Range Values | ||||
Measurement Ranges | |||||
SpO2 | 0-100% | ||||
Pulse rate | 30-350bpm | ||||
NIBP | Systolic:40 to 270 mmHg Mean Arterial:30 to 220 mmHg Diastolic:20 to 200 mmHg |
||||
RESP | 0-150rpm | ||||
TEMP | 0-50? | ||||
Measurement Accuracy | |||||
SpO2 | 70-100% (±2%), <70% undefined | ||||
Pulse rate | ±2bpm/±2% take maximum | ||||
ETCO2 | 0~40mmHg ±2mmHg, 41~150mmHg ±10% | ||||
TEMP | ±0.2? | ||||
RESP | ±1rpm | ||||
Resolution | |||||
Display | 800 X 480 | ||||
SpO2 | 1% | ||||
ETCO2 | 0.1mmHg | ||||
TEMP | 0.1? | ||||
RESP | 1rpm | ||||
Pulse rate | 1bpm | ||||
Electrical | |||||
AC power requirement | 100-240VA, 50/60Hz | ||||
Power comsumption | 60VA,FUSE T1.5A | ||||
Batteries | |||||
Types | Lithium-lon Batteries | ||||
Operating time | ≥4hours | ||||
Charge time | ≤4hours | ||||
Environment | |||||
Operating tempearture | 0-50? | ||||
Storage temperature | -40-75? | ||||
Operating humidity | 15-95% | ||||
Storage humidity | 10-95% | ||||
Operating altitude | -500-5000m | ||||
Standards and Certification | |||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | ||||
IEC 62304 | Medical device-software life cycle processes | ||||
MDD 93/42/EEC | European Medical Device Directive | ||||
ISO 13485 | Medical equipment-Quality management system | ||||
EN ISO 14971 | Medical devices-Risk management | ||||
EN 60601-1 | Medical electrical equipment | ||||
EN 60601-2 | Medical electrical equipment | ||||
EN 60601-8 | Medical electrical equipment | ||||
EN 980 | Symbols for use in labeling of medical devices | ||||
EN 1041 | Information supplied by the manufacture of medical devices | ||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | ||||
EN ISO 10993-1 | Biological evaluation of medical devices | ||||
EN ISO 10993-5 | Biological evaluation of medical devices | ||||
EN ISO 10993-10 | Biological evaluation of medical devices | ||||
ISO 14155-1 | Clinical investigation of medical devices | ||||
CE | CONFORMITE EUROPEENNE | ||||
SFDA | State Food and Drug Administration |
To contact Utech Medical Device Pty Ltd about UTMD 12" Multiparameters Veterinary Patient Monitor with ECG Resp | PM6000P use Get a quote.